Transformer Test

Measure turns ratio, no-load current and winding resistance of transformers.

See Also: Transformers, Transformer Testers, Current Transformer Test, Current Transformer Test Set


Showing results: 211 - 225 of 412 items found.

  • IEC61588 And IEC60065 Mandrel Test Apparatus

    CX-M01 - Shenzhen Chuangxin Instruments Co., Ltd.

    IEC61588 and IEC60065 Mandrel Test Apparatus is designed and manufactured in accordance with the standard requirements of IEC61558 and IEC60065. The IEC61588 and IEC60065 Mandrel Test Apparatus is used for the insulating thin layer of the power transformer and supply unit as well as the similar products to do the spindle test, mechanical strength test and abrasion test.

  • Distribution Transformer Tester

    NDB-DOC™ - ndb Technologies Inc.

    The NDB-DOC™ is a test instrument designed for distribution networks transformers from 10kVA to 2500kVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The NDB-DOC™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.

  • Distribution Transformer Tester

    DOC-2000™ - ndb Technologies Inc.

    The DOC-2000™ is a test instrument designed for distribution networks transformers up to 167KVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The DOC-2000™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.

  • HV AC Voltage Test Systems

    Fivestar HV Testing Equipment Co., Ltd.

    FSHV offers three different types of AC voltage test systems, the conventional type is AC test transformer design, mainly for testing objects of medium & low capacitance products, particularly for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (like inductive voltage transformers). Another is AC resonant test systems, according to series resonance circuit XL=XC (2πfL=1/2πfC), by setting F frequency of power supply or L inductance of reactor, generate a pure sinusoidal waveform of the test voltage, and the required input power is only 1/Q. Variable frequency type operates in a frequency range from 20Hz to 300Hz, ideal for field commissioning test of power cables and GIS/GIL. Variable inductance type outputs continuous AC voltage of power frequency (50/60Hz), mainly for factory testing of high and ultra-high voltage cables, power transformers, GIS, etc.

  • Test Probe

    MP21 - Rod-L Electronics

    Ideal for hipotting transformers, PCBs and other small assemblies. Four-finger-trigger must extend probe tip before the test can begin. The tester will shut down if the trigger is released

  • Three-Phase Transformer Winding Resistance Meters

    TWA Standard Series - IBEKO Power AB

    When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.

  • Transformer Turns Ratio Meter

    TTRM 102 - Scope T&M Pvt, Ltd.

    SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types.  TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.

  • Transformer Winding Resistance Meters

    TWA Advanced Series - Amperis sl

    The TWA advanced series instruments are designed for six-winding resistance measurement and simultaneous three phase on-load tap changer analysis of both the primary and the secondary transformer windings. This is performed with a one singlestep cable setup, with test currents of up to 40A. Each transformer configuration has a special measurement algorithm which is optimized for the fast stabilization of test results. The TWA instruments generate a true DC ripple-free current. Both the injection of the current and the discharge of energy from the magnetic circuit are automatically regulated.

  • Transformer Winding Resistance Meters

    TWA Standard Series - Amperis sl

    The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.

  • Triple Frequency Generator

    SFH264 Series - Shanghai Launch Electric Co., Ltd.

    This series of generators are mainly used to generate tripe frequency induced voltage for high voltage transformers. It also could be used for transformers in insulation induced voltage withstanding tests among windings, turns, sections and phases.The device is composed of triple frequency generator, console and reactor, with good waveforms output, reliability, and easy operation. Devices in different specification could be customer-made on request.

  • Primary Current Injection Test Set

    T 2000 - Altanova Group

    T 2000 is a portable current transformer test set which allows to perform many different measurements such as saturation, ratio and polarity tests and CT winding resistance test. Substation maintenance and commissioning test equipment, T 2000 is extremely appreciated by electrical engineers for its high accuracy and portability.

  • Fully Automatic Transformer Turns Ratio Tester

    DY100 - Neutronics Manufacturing Co.

    DY-100 is a new generation, fully automatic, transformer turns ratio tester designed for measuring ratio, ratio error of single and three phase transformers. The entire test is done automatically and quickly. Operator enters the test parameters and DY-100 tak es over; powers up the voltage, balances the bridge, takes the readings, and displays the results on the LCD screen. Prints testresults through its built-in printer. A key feature of the DY-100 is automatic measure transformer connection group. LV and HV windings are automatically isolated once the measurement is over. True portability is achieved by the lightweight (only 10 kg), single unit design housing the DY-100. The DY-100 is encased in an aluminum alloy cabinet.

  • Double Voltage Double Frequency Generator Setup

    DVDF - AJIT Electronics Co.

    This test setup is generally used to perform induced voltage test on the transformers. This set up consists of the USED motor and generator combination to develop the required voltage and frequency. Both generating unit and the drive motor are mounted on a common metallic frame.

  • Automatic Insulation Oil Tester

    KVIO-80 - KV Hipot Power Test Equipment Co.,Ltd

    Automatic Insulation Oil Breakdown Tester Is Used to carry on power frequency dielectric break down test on the transformer oil, capacitor oil, electric device, insulation tool etc.

  • AC/DC Withstand Voltage Test

    WB2671A/WB2671B - Lisun Electronics Inc.

    • Output voltage: 0-5kV (AC/DC); • Cutoff current range: AC 0~20mA (WB2671A)/0~100mA (WB2671B); DC 0-20mA; • Test time: 1-60s; • Transformer capacity: 750VA.